Seismic evaluation and retrofit studies of Bank Saderat Iran’s 4-stores building- Industrial Branch ...
Controlling and checking the structure’s implementation details, verification of the structure’s gravity and seismic resisting system, controlling the structural ductility and the serviceability regulations of Mehrabad Airport’s Multi-storey Car Park ...
Strengthening studies of vulnerable points in the floors of -1 and -2 stores of Mehrabad Airport’s Multi-storey car park and presenting the strengthening plan by using FRP systems ...
Executing the structural retrofitting project of Arya Sasol Petrochemical Company’s administrative building including carbon fiber polymer composite (CFRP) installation in order to reinforce the floors concrete joists. ...
Executing the project of axial-bending strengthening of Ladan Residential Tower’s vulnerable columns by using the FRP strengthening systems ...
Pressure injection of non-shrink grout under the 120 Base plates attached to the foundation with dimensions of approximately 1000 × 1000 mm2, Tehran-Iran ...
Design and execution of anchoring to concrete systems for connecting the new structural elements to the existing beams and columns, Karaj-Iran ...
Design and execution of anchoring to concrete systems for strengthening and retrofitting of existing floor slabs, Tehran-Iran ...
Pressure injection of non-shrink grout under the 80 Base plates attached to the foundation with dimensions of approximately 800 × 800 mm2, Tehran-Iran ...
Pressure injection of non-shrink grout under the Base plates attached to the top of 30 bridge columns of Saeed Abad Bridge, with dimensions of approximately 800 × 820 mm2, Tehran-Iran ...
Pressure injection of non-shrink grout rear the Base plates attached to the central shaft with dimensions of approximately 1.2 × 2 m2, Tehran-Iran ...
Seismic evaluation, Planning and designing concrete repair and seismic rehabilitation of Admin and Canteen buildings in Sirjan power plant, Sirjan-Iran ...
Planning and designing of concrete repair and seismic evaluation and rehabilitation of Hura 9-storey concrete structure in Tehran-Iran ...
Vulnerability assessment and retrofitting of pool and sauna building in Khomeini Shahr gym, Eslamshahr-Iran ...
Seismic evaluation and rehabilitation of 2-storey masonry building, BSI, Monirieh Branch (Code 96), Tehran-Iran ...
Seismic evaluation and rehabilitation of the 8-storey concrete structure to enhance a floor, Tehran-Iran ...
Seismic evaluation and seismic rehabilitation of the existing 5-storey concrete building in Zanjan Telecommunication Center (Hidaj Building), Zanjan-Iran ...
Seismic evaluation and seismic rehabilitation of the existing 5-storey concrete building in Zanjan telecommunication center (Setad Building), Zanjan-Iran ...
Seismic evaluation and seismic rehabilitation of the over 15 schools in Mshhad-Iran ...
Seismic evaluation and seismic rehabilitation of the over 30 schools in areas 10, 11, 12, 13 in Tehran and Damavand-Iran ...